How to Perform Collet Maintenance <DWX-53DC>
Performing regular collet maintenance prevents spindle issues. The process requires approximately 10 minutes.
A collet maintenance reminder will appear on the VPanel every 200 milling hours*. Please carry out the maintenance when the message is displayed.
* With slight variation depending on the work situation.
** This feature requires firmware version v460 or later and VPanel version v4.12.0 or later.
*** You can check the time elapsed since the last collet maintenance on the VPanel.
Please refer to the following pages for details: How to Perform Collet Maintenance <DWX-53D>